Custom 3.5 × 10 mm Enameled Aluminum Flat Wire

Customer Service
Technical Support
Service Efficiency
5/5
OVERALL SCORE
Specifications
Conductor:Aluminum
Insulation layer:single
Thermal Class:180℃
Insulation materials:polyesterimide
Shape:Flat/Rectangular
Size:3.5*10 mm
Advantages
Wide Range of Applications
Heat Resistance
Chemical Resistance
High Reliability and Longevity
Mechanical Durability
Cost-Effective

Specify rectangular winding wire around the dimensions, insulation requirements, and forming conditions your equipment needs. This 3.5 × 10 mm enameled aluminum flat wire, identified as model Q(ZY/XY)LB/2-180, provides a documented reference for evaluating custom winding applications.

The supplied test report covers conductor dimensions, finished dimensions, elongation, coating adherence, bending, breakdown voltage, resistivity, thermal shock, and appearance. The overall test conclusion is PASS.

For custom orders, use the reported specification as a starting point. Final dimensions, acceptance criteria, packaging, and delivery requirements should be defined in the purchase specification.

What Is Enameled Aluminum Flat Wire?

Enameled aluminum flat wire is a rectangular aluminum conductor covered with an electrically insulating enamel coating. It is also called enameled rectangular aluminum winding wire.

The aluminum conductor carries current. The enamel coating provides electrical insulation between adjacent turns. The rectangular profile allows engineers to arrange conductors in defined layers and evaluate how the winding fits within the available space.

The 3.5 × 10 mm designation refers to the nominal bare conductor dimensions, before the enamel coating is included. Winding layouts, guides, and tooling must account for the finished wire dimensions and their specified tolerances.

Product Specifications and Test Results

The following values come from the supplied test report. They describe the tested material and should not be treated as guaranteed measurements for every future production lot.

Test ItemReported RequirementReported Result
Conductor thickness3.45–3.55 mm3.485 mm
Conductor width9.93–10.07 mm9.976 mm
Corner radius0.8 mm0.8 mm
Thickness increase from enamel, A−a0.12–0.17 mm0.138 mm
Width increase from enamel, B−b≥0.12 mm0.154 mm
Overall thickness3.57–3.72 mm3.623 mm
Overall width10.05–10.24 mm10.13 mm
Elongation≥20.0%40%
Adherence, cutting and 3d winding test≤3.6 mm1 mm
BendingNo crackingPASS
Breakdown voltage at room temperature≥2,500 V5,200 / 5,300 / 5,100 / 6,200 / 7,100 V
Electrical resistivity at 20°C≤0.02800 Ω·mm²/m0.02768 Ω·mm²/m
Thermal shockNo crackingPASS
AppearanceNo oil, cracks, spots, bubbles, or impuritiesPASS

The report lists IEC 60317-73 as the applicable standard and July 6, 2026, as the test date.

Dimensional note: A−a and B−b represent the differences between finished and bare conductor dimensions in their respective directions. They are not single-side enamel thickness measurements.

What the Test Data Means for Your Design

Dimensions for Winding Layout and Tooling

Separate measurements for bare conductor size and finished wire size help engineers evaluate conductor placement, layer height, and tooling clearance.

The measured finished dimensions were 3.623 mm thick by 10.13 mm wide. Production tooling should accommodate the agreed tolerance limits, rather than relying only on these individual measurements.

This distinction matters when multiple turns or layers must fit within a restricted winding window. Small dimensional differences can accumulate across the assembly.

Forming Data for Process Evaluation

The reported 40% elongation, passing bend test, and adherence result provide useful information when evaluating winding and forming operations.

These results do not establish a universal minimum bend radius or winding tension. Actual processing conditions depend on the bending direction, tooling, winding speed, and handling method.

A trial using the intended equipment helps confirm that the conductor and enamel coating remain suitable after forming.

Measured Electrical Insulation Performance

The report includes five room-temperature breakdown voltage readings. Each exceeds the stated 2,500 V minimum requirement.

These measurements document insulation performance under the reported test conditions. They are not continuous operating voltage ratings for the wire or the finished equipment.

The operating voltage must be established through the equipment’s insulation design and applicable requirements.

Resistivity Data for Electrical Calculations

The reported resistivity is 0.02768 Ω·mm²/m at 20°C.

Engineers can use this value with conductor length and effective cross-sectional area to estimate resistance at the reference temperature. Operating-temperature calculations require an appropriate temperature adjustment.

Current capacity also depends on cooling, winding geometry, allowable temperature rise, and duty cycle.

Applications to Evaluate

This rectangular aluminum winding wire is a candidate for equipment designed to use aluminum conductors, including:

  • Transformer windings that require a defined rectangular conductor profile.
  • Reactor and inductor coils with specified layer dimensions.
  • Custom electromagnetic coils built around application-specific winding geometry.
  • Replacement winding projects where material, dimensions, insulation, and connections must match an approved design.

Application suitability should be established through engineering review and sample testing. The supplied report documents wire tests; it does not establish approval for a particular transformer, reactor, or finished assembly.

For replacement projects, confirm the original conductor material before selecting a substitute. A change between copper and aluminum affects resistance, conductor sizing, connections, and thermal performance.

How to Specify Custom Enameled Aluminum Flat Wire

A useful custom specification connects the wire dimensions to the actual winding process. Include the following information with your drawing or request for quotation.

Specification AreaInformation to Provide
Bare conductor geometryThickness, width, tolerances, and corner radius
Finished wire dimensionsMaximum overall thickness and width
Insulation requirementsRequired thermal class, coating requirements, and electrical acceptance criteria
Operating conditionsCurrent, voltage, ambient temperature, and allowable temperature rise
Forming requirementsBending direction, minimum bend radius, winding tension, and tooling details
Inspection requirementsStandard and edition, test methods, sampling plan, and required documentation
Supply requirementsSample quantity, order quantity, spool requirements, packaging, and requested delivery date

Dimensions in this report are metric. If your drawing uses inches, identify the controlling unit system and agree on converted tolerances before production.

The report does not establish the supplier’s full customization range. Alternate sizes, coating configurations, conductor alloy, and special packaging require confirmation during quotation.

Flat Wire vs. Round Wire

The right conductor shape depends on the winding design and manufacturing process.

Selection FactorEnameled Flat WireEnameled Round Wire
Cross sectionRectangular, with defined thickness and widthCircular, defined by diameter
Winding orientationRequires control of conductor orientationNo separate width and thickness orientation
Layer arrangementSupports organized rectangular conductor placementArrangement depends on wire diameter and winding pattern
Forming considerationsRequires attention to flatwise and edgewise bendingRequires attention to bend radius and winding tension
ToolingGuides and forming tools must match the profileGuides and tooling are selected around wire diameter

A rectangular profile can help use winding space efficiently in a suitable design. Actual fill factor depends on insulation thickness, clearances, corner geometry, and winding arrangement.

Changing conductor shape requires reviewing the complete winding design, including electrical and thermal performance.

Quality Documentation and Acceptance Criteria

The supplied report records a passing overall result for the listed tests. It provides a basis for reviewing the tested wire against the requirements shown in that document.

For purchasing, define the acceptance criteria before placing the order. Specify the applicable standard edition, dimensional limits, electrical tests, sampling requirements, and production-lot documentation.

The report does not identify the edition year of IEC 60317-73 or provide independent third-party certification. Any required certification should be requested separately and verified against the product being purchased.

For repeat orders, agree on how production lots will be identified and how inspection records will accompany the material. This supports traceability from incoming wire to the finished winding.

Frequently Asked Questions

Does 3.5 × 10 mm include the enamel coating?

No. It identifies the nominal bare conductor thickness and width. Finished dimensions include the enamel coating. Use the specified finished-size limits when designing winding guides, calculating layer height, or checking whether the wire fits within the available space.

Can this wire operate continuously at 7,100 V?

The report does not establish a 7,100 V continuous operating rating. That value is one breakdown test result at room temperature. Working voltage depends on the equipment’s insulation system, operating environment, electrical stresses, and applicable design requirements.

Does the “180” in the model mean the equipment can run continuously at 180°C?

The “180” designation generally identifies the wire’s thermal class. It does not independently establish the allowable operating temperature of a complete assembly. Equipment temperature limits must account for the full insulation system, expected service life, cooling conditions, and temperature rise.

What is the current rating of 3.5 × 10 mm aluminum flat wire?

A single current rating cannot be established from nominal dimensions alone. Current capacity depends on effective conductor area, winding construction, cooling, ambient temperature, and allowable temperature rise. The report provides resistivity data but does not specify an application-level current rating.

Can other sizes or insulation configurations be ordered?

Alternate dimensions and insulation requirements should be submitted for manufacturing review. The supplied report covers one size and model; it does not define available production limits. Include your drawing, operating conditions, and acceptance requirements when requesting an alternate configuration.

What are the minimum order quantity and lead time?

Minimum order quantity and lead time require a supplier quotation. Neither is specified in the report. Provide the requested quantity, sample requirements, spool configuration, and target delivery date so the quotation reflects the actual scope of your order.

Request a Quote for Your Winding Specification

Start with the dimensions and operating requirements that matter to your application. Submit your drawing, insulation requirements, expected order quantity, and requested delivery date for technical review.

For a new winding design, include sample testing and trial winding in the approval process. Confirm the final specification, inspection requirements, pricing, and delivery schedule before releasing the production order.